Baytech MRP units 2012 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel informatique Baytech MRP units 2012. BayTech MRP units 2012 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 67
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
2012
Copyright2012
BayTechnicalAssociates,Inc
12/1/2012
ModularRemote Power(MRP)
Vue de la page 0
1 2 3 4 5 6 ... 66 67

Résumé du contenu

Page 1 - ModularRemote Power(MRP)

2012Copyright2012BayTechnicalAssociates,Inc12/1/2012ModularRemote Power(MRP)

Page 2 - TableofContents

Page10CABLINGRJ45CableControl Module RJ-45 pin Signals Pin EIA 232 Signal Signal Direction Description 1 DTR Out +10V when activated by DCD.

Page 3

Page11RJ08X007 Standard Rollover Cable – RJ45 to RJ45 Serial 2: RJ08X007 Pin out Serial 3: RJ45 Receptacle & Plug Ada

Page 4

Page12RackMountHardwareTool Less hardware installed on back of unit. If hardware is not needed, remove with Phillips screwdriver. Instruc

Page 5 - COMPLIANCESTANDARD

Page13SERIALSETUP OperationImportant: OutletStatus  Connect the 9FRJ45PC-1 adapter to the user’s comp

Page 6 - CONNECTIONDESCRIPTION

Page14QUICKSTART:MRPSERIES OutletControlConfiguration: For those Administrators who have requested

Page 7 - INSTALLATION

Page15 EthernetConfiguration: Before continuing your System Administrator needs to tell you to use DH

Page 8

Page16 Figure 1: Outlet Status Help Menu: Type Help followed by a <CR> to view the line commands for the MRP outlet

Page 9 - UnitProcessors

Page17 Figure 3: Outlet Password Figure 4: Outlet Configuration Manage User Figure 5: Outlet Manage User Add a

Page 10 - CABLING

Page18Assigned Outlets Figure 6: Outlet Assignment Universal Ethernet Controller Configuration: Select a user

Page 11 - Adapters

Page19Figure 7: Network Menu Figure 8: Network Configuration Login Setup Menu Figure 9: Network Login Setup Access C

Page 12 - RackMountHardware

Page2TableofContentsCOMPLIANCESTANDARD...

Page 13 - SERIALSETUP

Page20Manage Users Figure 12: Network Manage Users Network Port Configuration Figure 13: Network Port Configuration

Page 14 - QUICKSTART:MRPSERIES

Page21DetailOperationsandConfigurations NETWORKMENUSingle Unit Menu CASCADE ENABLED Menu NOTE: O

Page 15 - EthernetConfiguration:

Page22OUTLETCONTROLLERSTATUSSCREEN MRP-10 Series (C) 2008 BayTech F1.12 True RMS Voltage True RMS C

Page 16

Page23OUTLETHELPOPTIONSOutlet 1: Outlet Control Help ReceptacleControlsOn,Off,Reboot,Lock,andUnlock

Page 17 - Enter new Password: *****

Page24STATUS This shows the current status of all circuit to the circuit breaker level. It shows Circuit Grou

Page 18

Page25OutletControlConfigurationMenuTo select the configuration menu, type ‘config’ at the prompt. Outlet 2: Outlet Configuration Man

Page 19

Page26DeleteaUser: RenameaUser: ChangeCircuitGroup: Enter user number to rename:Select R), changes th

Page 20

Page27--------------------------------------------| User | Assigned Outlets | | | C1,1| C1,2| C1,3| C1,4| ---------

Page 21 - NETWORKMENU

Page28 ChangeOutletName Enable/DisableConfirmation Select 3), adds all outlets to user access. Th

Page 22

Page29 Enable/DisableStatusMenu ChangeUnitID ChangeAlarmThreshold Unit ID: MRP--------------

Page 24

Page30 ChangeDisplayOrientation DisplayCurrentElectricalCharacteristics: Type “current” at the p

Page 25 - Enter user name:

Page31 LoggingOut CurrentUserPassword: IdentifyCurrentUser UnitIdentification Type “unitid” at the pr

Page 26 - Enter user number to rename:

Page32STATUSMENU Status Menu 1: Network Status OverallSystemStatus NetworkStatus LoggedUsers MemoryU

Page 27 - Enter Outlet number(s):

Page33 CurrentRoutingCache RouteSetup Processes UnitInfoDatabase Kernel IP routing cache Source

Page 28 - Enter :

Page34NETWORKCONFIGURATIONMENU: Menu 1: Network Configuration Status Copyright(C) Bay Technical Ass

Page 29

Page35 SerialPortConfiguration Menu 2: Serial Port Configuration Handshaking Status continued. Web S

Page 30

Page36 BaudRate WordSize Select word size: 1 For 5 2 For 6 3 For 7 4 For 8 Enter

Page 31 - UnitIdentification

Page37StopBits Parity RTS/DTRLineDriverInactivityState DTR Line Driver Inactive State is: HighHigh

Page 32 - STATUSMENU

Page38SerialPortDeviceName AttentionCharacter DisconnectTimeguard ConnectPortIDEcho Port ID Echo

Page 33 - UnitInfoDatabase

Page39LoginSetupMenuMenu 3: Network Login AccessControl ManageUsers Menu 4: Network Manage User Se

Page 34 - NETWORKCONFIGURATIONMENU:

Page4BAYTECHPRODUCTWARRANTY...

Page 35 - SerialPortConfiguration

Page40 NOTE: If you forget your password, the administrator has to delete the user then add them back in.

Page 36

Page41RadiusConfigurationMenu 5: Network Radius Configuration Radius login is...Disabl

Page 37

Page42TACACSConfiguration Menu 6: Network TACACS Configuration TACACS Server IP Address is: 0.0.0

Page 38 - ConnectPortIDEcho

Page43 Select 6), TACACSEncryptionEnable sets the TACACS+ encryption to off or on. Sending unencr

Page 39 - LoginSetupMenu

Page44NetworkPortConfigurationMenu 7: Network Port Configuration IPAddress SubnetMask The Subnet

Page 40

Page45GatewayAddress InactivityTimeout CarriageReturnTranslation BreakLength DHCPEnable/Disable TelnetEnable/Di

Page 41

Page46SSHEnable/Disable SSHHostKeyGeneration IPFilterConfigurationMenu 8: Network IP Filter Configuration

Page 42

Page47 SNMPConfigurationMenu 9: Network SNMP Configuration Delete Filter MenuEnter rule number to delete

Page 43 - ACACS server port is: 49

Page48 Community String: WebServerConfigurationMenu 10: Web Server Configuration Select 5), ‘SNMPRe

Page 44 - NetworkPortConfiguration

Page49 ModuleName RPCManagementMenu 11: Network RPC Management TemperatureAlarmThreshold Select 1), Web

Page 45

Page5 ABOUTTHISMRPOWNER’SMANUAL COMPLIANCESTANDARD This document provides information required for i

Page 46

Page50UnderVoltageAlarmThreshold OverVoltageAlarmThreshold LowCurrentAlarmThreshold EnvironmentalSensors Indivi

Page 47

Page51AllSensors OutletGroups ListOutletGroups AddGroup For configuration of all sensors of select

Page 48

Page52 DeleteGroup RenameGroup ModifyOutletsinaGroup DeleteAllOutletGroups Outlet group is currently

Page 49 - RPCManagement

Page53TemperatureUnits(degreesC/F) RPCCascadeModeMenu 12: Network RPC Cascade Mode CascadeModeEnable CascadeMod

Page 50

Page54 Module: 1 Attention Character: MRP05 (2 ,1)...1 Master Unit Outlet Contro

Page 51

Page55PowerFactorThresholdMenu IndividualUnits Breaker List for device 1, MRP-27 Ckt PF Thresho

Page 52

Page56 Outlet Thresholds for device 1, MRP-27 Threshold values listed next to outlet number. Enter o

Page 53

Page57 AllCircuits/OutletsPowerFactorThreshold AllCircuits/OutletsPowerThreshold Outlet Circuit

Page 54

Page58 Firmware/ConfigDownloadMenu 13: Network Firmware/Config Download EnableFirmwareUpgrade EnableSSLCertUp

Page 55

Page59 EnableConfigurationFileUpload RestoreConfigurationDefaults Select 4), allows the admin to resto

Page 56

Page6 CONNECTIONDESCRIPTION EIA232SerialConnection 10/100BaseTNetworkPortConnection ModemCommunica

Page 57

Page60 GetCurrentConfigurationFile DisplayConfigurationErrorLog EnableRelCtl.FirmwareUpgrade S

Page 58 - Firmware/ConfigDownload

Page61 UNITRESET LOGOUT Select RU), resets the unit to the current configurations, the unit will display: R

Page 59

Page62BAYTECHPRODUCTWARRANTY Exceptions BayTechExtendedWarranty Bay Technical Associates (BayTech)

Page 60

Page63TechnicalSupport RepairPolicy BayTech offers Tech Support for the lifetime of the product. A

Page 61 - UNITRESET

Page64ReturnAuthorizationProcess: a. Contact BayTech via Phone, Fax, or Email to get a Return Authorization (RA) Number. IMPO

Page 62 - BAYTECHPRODUCTWARRANTY

Page65APPENDIX:TACACSCONNECTIONSCENERIOS Different username and password in TACACS+ and power strip:

Page 63 - RepairPolicy

Page66APPENDIX:LCDDISPLAYDESCRIPTION ========================================================================= =====================

Page 64

Page67 APPENDIX:LEDDISPLAYDESCRIPTION Basic (3) LED display controller, CM03 and CM04 will display the current. The number of circuit breakers

Page 65

Page7INSTALLATIONUnpacking PreparingtheInstallationSite Power Compare the unit and serial number of the eq

Page 66

Page8 CAUTION: This unit is intended for indoor use only. Do not install near water or expose this unit

Page 67 - APPENDIX:TROUBLESHOOTING

Page9CircuitBreaker UnitProcessors Depending on if the unit has circuit breakers, in the case of pow